Rotary Attachment Error: Failed to Obtain Cup Length (Low Probability)

Fault Phenomenon

Pop-up prompt appears on the App or PC: Measurement failed due to sensor issue. Please reinstall the rotary printing attachment and try again.

 

Cause Analysis

The value detected by the Hall sensor is outside the supported range of 65 mm to 250 mm.

 

Troubleshooting Steps

  1. Confirm that the cup height is within 65 mm – 250 mm. Cups outside this range are not supported.

  2. If the cup height meets the specification but the error persists, the Hall sensor may be damaged. Contact after-sales service for repair.

 

Support Contact

If the issue persists after completing the above steps, please contact eufyMake Customer Support at support@eufymake.com with the following information:

Unresolved icon
197 undefined
Download icon
UL Exposure Assessment Report for the eufyMake UV Printer E1
Download icon
Test Diagram Project File
Download icon
eufyMake Rotary Printing Attachment for UV Printer E1 Quick Start Guide
Download icon
eufyMake UV Printer E1 Quick Start Guide
Download icon
eufyMake Laminating Machine for UV Printer E1 Quick Start Guide
Download icon
eufyMake UV Printer E1 Brugervejledning (V8260)
View More
Play videoeufyMake E1 Tutorial | Part 13: Door Panel Replacement
eufyMake E1 Tutorial | Part 13: Door Panel Replacement
Play videoeufyMake E1 Tutorial | Part 3: Main Printing Workflow
eufyMake E1 Tutorial | Part 3: Main Printing Workflow
Play videoeufyMake E1 Tutorial Part 15: Printer Deep Maintenance
eufyMake E1 Tutorial Part 15: Printer Deep Maintenance
Play videoeufyMake E1 Tutorial Part 10: Ink Cartridge and Cleaning Cartridge Replacement
eufyMake E1 Tutorial Part 10: Ink Cartridge and Cleaning Cartridge Replacement
Play videoeufyMake E1 Tutorial Part 19: Encoder Strip Replacement
eufyMake E1 Tutorial Part 19: Encoder Strip Replacement
Play videoeufyMake E1 Tutorial Part 18: Printer Outer Shell Disassembly and Assembly
eufyMake E1 Tutorial Part 18: Printer Outer Shell Disassembly and Assembly
View More